SERVICE
Table Tilt Calibration
Whenthetabletiltissetto0˚,thetableshouldbe
positioned perpendicular to the sanding disc face. If not
follow this procedure.
To calibrate the table tilt, do these steps:
1. DISCONNECT MACHINE FROM POWER!
2. Using a try square or machinist’s square, set one
edge on the table surface and the other against the
face of the disc, as shown in Figure 17.
Note: This can be done with the sandpaper
installed, although it is somewhat more precise if
the sandpaper is not installed.
3. Loosen the lock handles and adjust the table angle
until it is perfectly perpendicular to the disc, then
tighten the lock handles while holding the table in
place.
4. If the angle pointer stickers on both ends do not
pointto0˚,removethemandplacethemonthe
trunnionsotheypointto0˚.
5. Recheck the scale accuracy with the square.
Figure 17. Squaring the table.