Model W1778 18 Gauge Deep Stapler Kit
-5-
The Model W1778 is designed to be
operated at 70-100 PSI using clean,
dry, regulated, compressed air. Do not
exceed the 120 PSI maximum operating
pressure for your model.
Before using your new stapler, regulate
the air pressure to find the optimum
setting within the specified operating
range. Start by testing the stapler at
a low setting, then increase the air
pressure as needed for satisfactory
results.
An in-line filter/lubricator/regulator unit,
can be installed as depicted in Figure 1.
This filter/lubricator/regulator unit
will protect your tool from damaging
water build-up, allow you to adjust and
maintain regulated air pressure to your
tool, and save you the inconvenience of
having to manually lubricate your tool
every time you use it.
If you plan on installing a filter/
lubricator/regulator unit in your
compressed air system, always follow the
connection instructions that come with
the unit.
















Figure 1. Typical filter/lubricator/regulator installation order.
Compressed Air System
Exceeding the maximum permissible
operating pressure may damage the
stapler and cause it to malfunction.
To protect yourself from personal
injury, DO NOT allow the air pressure
to exceed the recommended
pressure for this stapler!